Home / Methods / Engineering / Simply supported beam: moment, stress, deflection
Simply supported beam: moment, stress, deflection
Will a beam, joist, lintel or shelf hold: a preliminary strength and deflection check for a loaded span.
Or ask in your own words (needs an AI key)
What you need
- span, m
- uniform load, kN/m (default 0)
- point load at mid-span, kN (default 0)
- elastic modulus, GPa (steel ≈ 200, timber ≈ 10, concrete ≈ 30) (default 200)
- second moment of area, cm⁴
- section modulus, cm³
- rectangular section width, mm
- rectangular section height, mm
- allowable stress of the material, MPa
- deflection limit: span divided by … (default 250)
What it calculates
- maximum bending moment, kN·m
- maximum stress in the section, MPa
- mid-span deflection, mm
- allowed deflection, mm
- strength utilisation, %
- reaction at each support, kN
Examples
Steel, 6 m span, 10 kN/m, IPE 270 (I = 5,790 cm⁴, W = 429 cm³)
| maximum bending moment | 45 kN·m |
| maximum stress in the section | 104.895 MPa |
| mid-span deflection | 14.5725 mm |
| allowed deflection | 24 mm |
| strength utilisation | 49.95 % |
| reaction at each support | 30 kN |
Timber joist 50 × 200 mm, 4 m span, 1.5 kN/m, E = 10 GPa, allowable 10 MPa, deflection L/300
| maximum bending moment | 3 kN·m |
| maximum stress in the section | 9 MPa |
| mid-span deflection | 15 mm |
| allowed deflection | 13.3333 mm |
| strength utilisation | 90 % |
| reaction at each support | 3 kN |
Example numbers are checked against an independent calculation. The AI in Numo does not compute: it only parses your question; a deterministic engine does the maths.
Careful
A preliminary check, not a design: no code safety factors, no self-weight (add it to the uniform load), no lateral-torsional stability.
Typical mistakes
- Using the section modulus instead of the second moment of area for deflection (or vice versa) — off by a large factor.
- Checking only strength: timber and long beams more often fail on deflection.
- Mixing kN and kgf: 1 kN ≈ 102 kgf.
More in this family «Engineering»
- Pipe pressure drop (Darcy–Weisbach)
- Availability (SLA): what it means in downtime and what redundancy gives
- Reliability: probability of failure-free operation from MTBF and availability
- Stress and safety factor of a part
- Cable size by voltage drop
- Design load: permanent and variable actions with partial factors
- Column buckling (Euler)