Home / Methods / Engineering / Column buckling (Euler)
Column buckling (Euler)
A post, support or prop: at what force the member buckles sideways and whether there is margin.
Or ask in your own words (needs an AI key)
What you need
- elastic modulus, GPa (default 200)
- smallest second moment of area, cm⁴
- column length, m
- effective length factor (1 pinned, 0.7, 0.5 fixed, 2 cantilever) (default 1)
- compressive load, kN
- section area, cm² (for slenderness)
What it calculates
- critical buckling load, kN
- buckling safety factor, times
- slenderness ratio
Examples
Steel, I = 8,356 cm⁴, 3 m, pinned, 500 kN
| critical buckling load | 18,325.85 kN |
| buckling safety factor | 36.6517 times |
Timber post 100 × 100 mm (I = 833 cm⁴, A = 100 cm²), 2.7 m, pinned, 50 kN, E = 10 GPa
| critical buckling load | 112.821 kN |
| buckling safety factor | 2.2564 times |
| slenderness ratio | 93.5308 |
Example numbers are checked against an independent calculation. The AI in Numo does not compute: it only parses your question; a deterministic engine does the maths.
Careful
Euler is valid for slender members (for steel — slenderness above ~100); stocky ones crush first, and Euler overestimates them.
Typical mistakes
- Using the larger second moment: a column buckles about its weakest axis.
- Using K = 0.5 for a post that merely bears on its supports: full fixity is rare, and the mistake overstates the critical load fourfold.
More in this family «Engineering»
- Simply supported beam: moment, stress, deflection
- Pipe pressure drop (Darcy–Weisbach)
- Availability (SLA): what it means in downtime and what redundancy gives
- Reliability: probability of failure-free operation from MTBF and availability
- Stress and safety factor of a part
- Cable size by voltage drop
- Design load: permanent and variable actions with partial factors