Home / Methods / Engineering / Pipe pressure drop (Darcy–Weisbach)
Pipe pressure drop (Darcy–Weisbach)
Water supply, irrigation, heating, a process line: how much pressure the pipe eats and whether the pump is enough.
Or ask in your own words (needs an AI key)
What you need
- flow rate, m³/h
- inner diameter, mm
- length, m
- wall roughness, mm (steel 0.05, plastic 0.007) (default 0.05)
- fluid density, kg/m³ (default 1,000)
- viscosity, mPa·s (water at 20 °C — 1.0) (default 1)
What it calculates
- flow velocity, m/s
- Reynolds number
- friction factor
- pressure drop, kPa
- head loss, m
Examples
Water, 10 m³/h, Ø50 mm, 100 m, steel
| flow velocity | 1.4147 m/s |
| Reynolds number | 70,735.5 |
| pressure drop | 46.34 kPa |
Oil 870 kg/m³, 100 mPa·s: 2 m³/h, Ø50 mm, 30 m — laminar
| flow velocity | 0.2829 m/s |
| Reynolds number | 123.08 |
| friction factor | 0.52 |
| pressure drop | 10.865 kPa |
| head loss | 1.2735 m |
Example numbers are checked against an independent calculation. The AI in Numo does not compute: it only parses your question; a deterministic engine does the maths.
Careful
Straight runs only; bends, valves and filters add local losses. Water velocity is usually kept around 0.5–2 m/s.
Typical mistakes
- Using the outer instead of the inner diameter: losses depend strongly on diameter (to the fifth power).
- Treating a glycol heat-transfer fluid as water: its viscosity is several times higher, which changes the flow regime and the pressure drop.
More in this family «Engineering»
- Simply supported beam: moment, stress, deflection
- Availability (SLA): what it means in downtime and what redundancy gives
- Reliability: probability of failure-free operation from MTBF and availability
- Stress and safety factor of a part
- Cable size by voltage drop
- Design load: permanent and variable actions with partial factors
- Column buckling (Euler)