Home / Methods / Engineering / Stress and safety factor of a part
Stress and safety factor of a part
Tension or shear in a bolt, rod, cable or bracket: will the section hold and what size is needed.
Or ask in your own words (needs an AI key)
What you need
- force, kN
- cross-section area, mm²
- yield strength, MPa (S235 steel — 235)
- required safety factor (default 1.5)
What it calculates
- stress in the section, MPa
- safety factor, times
- minimum area for the required factor, mm²
Examples
50 kN on 400 mm², 235 MPa steel
| stress in the section | 125 MPa |
| safety factor | 1.88 times |
| minimum area for the required factor | 319.149 mm² |
An M12 class 8.8 bolt in tension: 20 kN, 84.3 mm² stress area, 640 MPa, factor 2
| stress in the section | 237.248 MPa |
| safety factor | 2.6976 times |
| minimum area for the required factor | 62.5 mm² |
Example numbers are checked against an independent calculation. The AI in Numo does not compute: it only parses your question; a deterministic engine does the maths.
Careful
Uniform stress without stress raisers (holes, threads, notches multiply it) and without fatigue from repeated loading.
Typical mistakes
- Using the full area of a bolt instead of the threaded (tensile stress) area.
- Comparing the stress with the ultimate strength instead of the yield strength: the part deforms permanently long before it breaks.
More in this family «Engineering»
- Simply supported beam: moment, stress, deflection
- Pipe pressure drop (Darcy–Weisbach)
- Availability (SLA): what it means in downtime and what redundancy gives
- Reliability: probability of failure-free operation from MTBF and availability
- Cable size by voltage drop
- Design load: permanent and variable actions with partial factors
- Column buckling (Euler)