Home / Methods / Engineering / Design load: permanent and variable actions with partial factors
Design load: permanent and variable actions with partial factors
Reduce loads to the design value for a strength check: permanent and variable with partial factors, and compare with the resistance.
Or ask in your own words (needs an AI key)
What you need
- permanent load: self-weight, layers, fixed equipment
- variable load: people, furniture, snow, wind
- partial factor for the permanent load (default 1.35; norm: 1.35 — EN 1990 (Eurocode 0), Annex A1; ASCE 7 uses 1.2)
- partial factor for the variable load (default 1.5; norm: 1.5 — EN 1990 (Eurocode 0), Annex A1; ASCE 7 uses 1.6)
- resistance of the section or member (same units)
What it calculates
- design load: γG × permanent + γQ × variable
- characteristic load: the sum without factors
- overall factor: design over characteristic, ×
- utilisation of resistance (over 100% — fails), %
Examples
Permanent 12, variable 8, factors 1.35 and 1.5, resistance 35
| design load: γG × permanent + γQ × variable | 28.2 |
| characteristic load: the sum without factors | 20 |
| overall factor: design over characteristic | 1.41 × |
| utilisation of resistance (over 100% — fails) | 80.5714 % |
Variable only, no resistance
| design load: γG × permanent + γQ × variable | 7.5 |
| characteristic load: the sum without factors | 5 |
| overall factor: design over characteristic | 1.5 × |
Example numbers are checked against an independent calculation. The AI in Numo does not compute: it only parses your question; a deterministic engine does the maths.
Careful
One basic combination for the ultimate limit state. Several variable actions with combination factors, accidental actions and seismic combinations are not included; for a design use the codes in force and an engineer’s calculation.
Typical mistakes
- Checking strength with characteristic loads: strength is checked with design loads, increased by partial factors.
- Using the same factor for permanent and variable: variable loads get a higher factor because they are less certain.
- Comparing a design load with the characteristic material strength: the design resistance is needed.
More in this family «Engineering»
- Simply supported beam: moment, stress, deflection
- Pipe pressure drop (Darcy–Weisbach)
- Availability (SLA): what it means in downtime and what redundancy gives
- Reliability: probability of failure-free operation from MTBF and availability
- Stress and safety factor of a part
- Cable size by voltage drop
- Column buckling (Euler)